Assembly Guide

  1. Measure the widtth of a board and pre-set the installation tool (double board width plus 10 mm).
  2. Set the pressure plate to the board thickness. Tighten the screws with the accompanying Allen wrench.
  3. Fasten one side of the first board with screws. On the opposite side, hammer in the first IGEL row with a hammer.
  4. Screw in the first IGEL row (max. 4 Nm).
  5. Place the next board.
  6. Position the board flush on the end.
  7. Put on the second IGEL row.
  8. Put on the pre-set installation tool. Press the board down firmly.
  9. Tighten the installation tool. The resulting joint should be a maximum of 5 mm. If applicable, readjust the installation tool while it is not tightened.
  10. Screw in the IGEL while it is in a tightened state (max. 4 Nm).

To be Observed

  • Do not exceed the recommended beam spacing of max 50 cm in the substructures!
  • Orientate the spacing of the supporting beams according to the load and plank size. For a normal load and size of 25 × 145 mm, this is approximately 60 cm, and for 45 × 145 mm it is approx. 90 cm.
  • If your covering joins in the length, please use two supporting beams.
  • The distance between the end of the board and the IGEL must be min. 3 cm.
  • Install with a slope of 1% for better water runoff.
  • Pre-drill the screws including the head to prevent crack formation.
  • Use two screws per board width; each one should be approx. 3 cm from the side edge.
  • Drill the screw holes approx. 5 to 7 cm from the end of the board.